Sell 8-Zone Alarm Control Panel with Communicator and Auto-Dialer
Sell 8-Zone Alarm Control Panel with Communicator and Auto-DialerContinuous Selling Item
Sell 8-Zone Alarm Control Panel with Communicator and Auto-Dialer
HA-982R -- Remote Keypad Controlled System
HA-982S -- Self-Contained Keypad System
Two 32 Digit Telephone Numbers for Communicator
Four 32 Digit Telephone Numbers for Auto-Dialer
Tone Dialing (DTMF) or Pulse Dialing with 3 Break Make Ratio Options
Communicator Data in DTMF Format with Check-Sum
Remote Arm-Disarm the Alarm System or Call for Status from Any DTMF Telephone or Mobile Phone
Programmable Pause Time between Any Digits - A key Function in Making Contact with the Auto-Pager Station
Conditions for Sending Status Report from Communicator
Alarm Occurs
System Status Change
Alarm System Armed
Alarm System Disarmed
Periodic Report
Station or Authorized Party Call for status
Auto-Dialer is Programmable with Voice Message and Numeric Message for Auto-Pager Calling
20 Seconds Non-volatile User Re-Programmable Voice Message
Controllable & Prolongable Listen-in Duration
Back-Up or Non-Back-up Dialing for Alarm Reporting
Automatic Faulty Telephone Line Detection at Alarm Arm-Disarm Control
Programmable of Dialing Attempts or Dialing Until the Line is Through for Communicator, 8 Attempts Maximum
Programmable of Recorded Message Repeats, 8 Repeats Maximum
Selection of Communicator & Dialer Calling Combinations
Periodic Report Interval Time Options
Telephone Numbers in Communicator & Auto-Dialer Can Be Tested Individually
Use the Existing Telephone Line, No Additional Line is Required
Compatible with All Kinds of Public Telephone Systems & Those PBX Systems Using Standard Telephone
8 Zones, Programmable for Instant, Delay 1 or 2, 24 Hour Instant or 24 Hour Silent Alarm Reporting
Programmable Master Code, Client Code & 8 User Codes
All User Codes are with Duress Function
Protection Zones are Programmable for Single or Multiple Triggering for Noise Pollution Regulations
Programmable Time for Exit Delay, Entry Delay 1 & 2, and Alarm Duration
Arm-Disarm by the On-Board Keypad or Remotely from Any DTMF Telephone or Mobile Phone
Programmable Response Time for Each Protection Zones
Arm-Disarm Ring Back Options
Exit and Entry Beep Enable-Disable Options
Instant Arming Codes for Home or Away Operation
Built-in Dynamic Battery Charger and Tester
Dynamic Battery Testing Can Be Performed Periodically or Manually by the User Anytime
On Board Activation of Panic and Duress
Self-Contained Keypad System - HA-982S
Remote Keypad Controlled System - HA-982R
Able To Take Up To 3 Remote Keypads (HA-982S & R)
Store the Habitually Isolated Zones in Memory or Manually Set Zone Isolation are Possible for Home Mode Operation
Home and Away Operations
Forced to Arm or Arm Prohibited Options
Instant-Delay Zones Handover/Non-Handover Operation Options
Connection Facilities for Siren/Bell, Satellite Siren and Strobe Light
Power Low watchdog Resets the System before Battery Exhausted
Non-Volatile Memory
Remote Arm-Disarm by Conventional Key-Switch is Possible, Good for Those People Do Not Like Codes
Factory Set Full Feature Default Value for Ready Use
Full Memory for Alarm Event Zone(s)
Tamper-Proof
Remote Keypad Can Be Fitted in a 2-Gang Electrical Box
Back-up Battery: 6.5AH 12V, Rechargeable Sealed Lead Acid (not Included)
16.5V AC Operation
Dimensions: Control Panel - 368 (H) x 215(W) x 74 (D) mm
Remote Keypad - 117 (H) x 117 (W) 21 (D) mm
HA-982R-PT / HA-982S-PT
for Built-in Power Transformer Version
HA-982S -- Self-Contained Keypad System
Two 32 Digit Telephone Numbers for Communicator
Four 32 Digit Telephone Numbers for Auto-Dialer
Tone Dialing (DTMF) or Pulse Dialing with 3 Break Make Ratio Options
Communicator Data in DTMF Format with Check-Sum
Remote Arm-Disarm the Alarm System or Call for Status from Any DTMF Telephone or Mobile Phone
Programmable Pause Time between Any Digits - A key Function in Making Contact with the Auto-Pager Station
Conditions for Sending Status Report from Communicator
Alarm Occurs
System Status Change
Alarm System Armed
Alarm System Disarmed
Periodic Report
Station or Authorized Party Call for status
Auto-Dialer is Programmable with Voice Message and Numeric Message for Auto-Pager Calling
20 Seconds Non-volatile User Re-Programmable Voice Message
Controllable & Prolongable Listen-in Duration
Back-Up or Non-Back-up Dialing for Alarm Reporting
Automatic Faulty Telephone Line Detection at Alarm Arm-Disarm Control
Programmable of Dialing Attempts or Dialing Until the Line is Through for Communicator, 8 Attempts Maximum
Programmable of Recorded Message Repeats, 8 Repeats Maximum
Selection of Communicator & Dialer Calling Combinations
Periodic Report Interval Time Options
Telephone Numbers in Communicator & Auto-Dialer Can Be Tested Individually
Use the Existing Telephone Line, No Additional Line is Required
Compatible with All Kinds of Public Telephone Systems & Those PBX Systems Using Standard Telephone
8 Zones, Programmable for Instant, Delay 1 or 2, 24 Hour Instant or 24 Hour Silent Alarm Reporting
Programmable Master Code, Client Code & 8 User Codes
All User Codes are with Duress Function
Protection Zones are Programmable for Single or Multiple Triggering for Noise Pollution Regulations
Programmable Time for Exit Delay, Entry Delay 1 & 2, and Alarm Duration
Arm-Disarm by the On-Board Keypad or Remotely from Any DTMF Telephone or Mobile Phone
Programmable Response Time for Each Protection Zones
Arm-Disarm Ring Back Options
Exit and Entry Beep Enable-Disable Options
Instant Arming Codes for Home or Away Operation
Built-in Dynamic Battery Charger and Tester
Dynamic Battery Testing Can Be Performed Periodically or Manually by the User Anytime
On Board Activation of Panic and Duress
Self-Contained Keypad System - HA-982S
Remote Keypad Controlled System - HA-982R
Able To Take Up To 3 Remote Keypads (HA-982S & R)
Store the Habitually Isolated Zones in Memory or Manually Set Zone Isolation are Possible for Home Mode Operation
Home and Away Operations
Forced to Arm or Arm Prohibited Options
Instant-Delay Zones Handover/Non-Handover Operation Options
Connection Facilities for Siren/Bell, Satellite Siren and Strobe Light
Power Low watchdog Resets the System before Battery Exhausted
Non-Volatile Memory
Remote Arm-Disarm by Conventional Key-Switch is Possible, Good for Those People Do Not Like Codes
Factory Set Full Feature Default Value for Ready Use
Full Memory for Alarm Event Zone(s)
Tamper-Proof
Remote Keypad Can Be Fitted in a 2-Gang Electrical Box
Back-up Battery: 6.5AH 12V, Rechargeable Sealed Lead Acid (not Included)
16.5V AC Operation
Dimensions: Control Panel - 368 (H) x 215(W) x 74 (D) mm
Remote Keypad - 117 (H) x 117 (W) 21 (D) mm
HA-982R-PT / HA-982S-PT
for Built-in Power Transformer Version
Company Profile
- Business Type:
- Manufacturer
- Country:
- Hong Kong (China)
- Employee Count:
- 60
- Established Year:
- 1979
- Brands:
- APO and AEI
- OEM:
- YES
- ODM:
- YES
- Existing Markets:
- World-wide
- Factory Location:
- Foshan, Guangdong
- OPA:
- NO
- Production Leadtime:
- 30 Days
- Offshore C/O:
- NO
- CMT:
- NO
- Monthly Productivity:
- 3,000 - 5,000 sets
- VAT:
- 17%
- Strengths:
-
- Wide product selection range in Security Industry
Contact Information
- Company Name:
- AEI PROTECT-ON SYSTEMS LIMITED
- Country:
- Hong Kong (China)
- Address:
- Flat B, 4/F., Effort Industrial Building, 2-8 Kung Yip Street, Kwai Chung, N.T., Hong Kong
- Website:
- http://www.aei-hongkong.com