IR Series Power Inverter 1KW-3KW
Rated Capacity 1000w 1500w 2000w 3000w
1.Input Model 120v Models 230v Models
Nominal Voltage 100V/110V/115V/120V Selectable 200V/220V/230V/240V Selectable
Input Frequency Nominal Input Frequency 50Hz/ 60Hz (Auto Detection)
Low Line Frequency Re-Connect :58+0.3Hz For 60Hz;
48+0.3Hz For 50Hz;
Low Line Frequency Disconnect :57+0.3Hz For 60Hz;
47+0.3Hz For 50Hz;
High Line Frequency Re-Connect: 64+0.3Hz For 60Hz;
54+0.3Hz For 50Hz;
High Line Frequency Disconnect: 65+0.3Hz For 60Hz;
55+0.3Hz For 50Hz;
Efficiency >95% (Normal Mode)
Noise Filtering Full Time EMI/RFI Filtering
Over Current
Protection By Re-Settable Over Current Protector
Voltage Range Nominal Input Voltage 230Vac( Selectable)
Low Line Disconnect 184Vac±4%
Low Line Re-Connect 194Vac ±4%
High Line Disconnect 265Vac±4%
High Line Re-Connect 255Vac±4%
Max AC Input Voltage 270VRMS
2.Output Model 120v Models 230v Models
Power Levels
Crated At
Nominal Inputs 1000W 1500W 2000W 3000W
Output Voltage 100V/110V/115V/120V Selectable 200V/220V/230V/240V Selectable
Voltage Waveform Pure Sine Wave
Crest Factor 3:1
Output Frequency Nominal Input Frequency 50Hz/ 60Hz (Auto Detection)
Low Line Frequency Re-Connect :
58+0.3Hz For 60Hz;48+0.3Hz For 50Hz;
Low Line Frequency Disconnect :
57+0.3Hz For 60Hz;47+0.3Hz For 50Hz;
High Line Frequency Re-Connect:
64+0.3Hz For 60Hz;54+0.3Hz For 50Hz;
High Line Frequency Disconnect:
65+0.3Hz For 60Hz;55+0.3Hz For 50Hz;
Regulation
(Nominal) ±10% Typical Of Nominal Voltage
Transfer Time Transfer Time : AC To DC : 10ms (Typical)
Transfer Time : DC To AC : 10ms(Typical )
Max Bypass
Overload Current 30A
3.Input Model 120V Models 230V Models
Nominal Voltage DC12V/24V DC12V/24V DC12V/24V DC24V/48V
Efficiency >80%
Noise Filtering Full Time EMI/RFI Filtering
Over Current
Protection By Re-Settable Over Current Protector
Voltage Range Min DC Start Voltage 10V/20V/40V
Low Battery Alarm 10.5Vdc ± 0.3Vdc
For 12V Battery;
21.0Vdc ± 0.6Vdc
For 24V Battery;
42.0Vdc ± 0.6Vdc
For 48V Battery
Low DC Input
Shut-Down 10.0Vdc ± 0.3Vdc
For 12V Battery
20.0vdc± 0.6Vdc
For 24V Battery;
40.0Vdc± 0.6Vdc
For 48V Battery
High DC Input
Alarm& Fault 16Vdc ± 0.3Vdc
For 12V Battery;
32Vdc ± 0.6Vdc
For 24V Battery;
64Vdc ± 0.6Vdc
For 48V Battery
High DC Input
Recovery 15.5Vdc ± 0.3Vdc
For 12V Battery;
31.0Vdc ± 0.6Vdc
For 24V Battery;
62.0Vdc ± 0.6Vdc
For 48V Battery
Surge Protection (110%Fault (Shutdown Output) After 15 Minutes;
(125%Fault (Shutdown Output) After 60s;
Load>150% ±10%:
Fault (Shutdown Output) After 20s
2000VA / 2700VA:440 Joules 324 Joules
4000VA / 5000VA:660 Joules
4.Output Power Levels
Crated At
Nominal Inputs 1000w/1500w/2000w/3000w
Output Voltage 100V/110V/115V/120V
Selectable 200V/220V/230V/240V
Selectable
Voltage Waveform Pure Sine Wave
Crest Factor 3:1
Output Frequency Nominal Input Frequency 50Hz ± 0.3Hz
Auto Tracking Main
Frequency(Hz) 50Hz @48-54Hz ;
60Hz @58-64Hz
Rated Capacity 1000w 1500w 2000w 3000w
1.Input Model 120v Models 230v Models
Nominal Voltage 100V/110V/115V/120V Selectable 200V/220V/230V/240V Selectable
Input Frequency Nominal Input Frequency 50Hz/ 60Hz (Auto Detection)
Low Line Frequency Re-Connect :58+0.3Hz For 60Hz;
48+0.3Hz For 50Hz;
Low Line Frequency Disconnect :57+0.3Hz For 60Hz;
47+0.3Hz For 50Hz;
High Line Frequency Re-Connect: 64+0.3Hz For 60Hz;
54+0.3Hz For 50Hz;
High Line Frequency Disconnect: 65+0.3Hz For 60Hz;
55+0.3Hz For 50Hz;
Efficiency >95% (Normal Mode)
Noise Filtering Full Time EMI/RFI Filtering
Over Current
Protection By Re-Settable Over Current Protector
Voltage Range Nominal Input Voltage 230Vac( Selectable)
Low Line Disconnect 184Vac±4%
Low Line Re-Connect 194Vac ±4%
High Line Disconnect 265Vac±4%
High Line Re-Connect 255Vac±4%
Max AC Input Voltage 270VRMS
2.Output Model 120v Models 230v Models
Power Levels
Crated At
Nominal Inputs 1000W 1500W 2000W 3000W
Output Voltage 100V/110V/115V/120V Selectable 200V/220V/230V/240V Selectable
Voltage Waveform Pure Sine Wave
Crest Factor 3:1
Output Frequency Nominal Input Frequency 50Hz/ 60Hz (Auto Detection)
Low Line Frequency Re-Connect :
58+0.3Hz For 60Hz;48+0.3Hz For 50Hz;
Low Line Frequency Disconnect :
57+0.3Hz For 60Hz;47+0.3Hz For 50Hz;
High Line Frequency Re-Connect:
64+0.3Hz For 60Hz;54+0.3Hz For 50Hz;
High Line Frequency Disconnect:
65+0.3Hz For 60Hz;55+0.3Hz For 50Hz;
Regulation
(Nominal) ±10% Typical Of Nominal Voltage
Transfer Time Transfer Time : AC To DC : 10ms (Typical)
Transfer Time : DC To AC : 10ms(Typical )
Max Bypass
Overload Current 30A
3.Input Model 120V Models 230V Models
Nominal Voltage DC12V/24V DC12V/24V DC12V/24V DC24V/48V
Efficiency >80%
Noise Filtering Full Time EMI/RFI Filtering
Over Current
Protection By Re-Settable Over Current Protector
Voltage Range Min DC Start Voltage 10V/20V/40V
Low Battery Alarm 10.5Vdc ± 0.3Vdc
For 12V Battery;
21.0Vdc ± 0.6Vdc
For 24V Battery;
42.0Vdc ± 0.6Vdc
For 48V Battery
Low DC Input
Shut-Down 10.0Vdc ± 0.3Vdc
For 12V Battery
20.0vdc± 0.6Vdc
For 24V Battery;
40.0Vdc± 0.6Vdc
For 48V Battery
High DC Input
Alarm& Fault 16Vdc ± 0.3Vdc
For 12V Battery;
32Vdc ± 0.6Vdc
For 24V Battery;
64Vdc ± 0.6Vdc
For 48V Battery
High DC Input
Recovery 15.5Vdc ± 0.3Vdc
For 12V Battery;
31.0Vdc ± 0.6Vdc
For 24V Battery;
62.0Vdc ± 0.6Vdc
For 48V Battery
Surge Protection (110%
(125%
Load>150% ±10%:
Fault (Shutdown Output) After 20s
2000VA / 2700VA:440 Joules 324 Joules
4000VA / 5000VA:660 Joules
4.Output Power Levels
Crated At
Nominal Inputs 1000w/1500w/2000w/3000w
Output Voltage 100V/110V/115V/120V
Selectable 200V/220V/230V/240V
Selectable
Voltage Waveform Pure Sine Wave
Crest Factor 3:1
Output Frequency Nominal Input Frequency 50Hz ± 0.3Hz
Auto Tracking Main
Frequency(Hz) 50Hz @48-54Hz ;
60Hz @58-64Hz
- Place of Origin:
- China
- Brand:
- Pbp
- Unit Price:
- USD 159
- Price Terms:
- FOB Shenzhen
- Packing:
- standard
- Payment Terms:
- L/C;T/T
- Delivery Time:
- 15 days
- Min Order Quantity:
- 15pcs
- Standard / Certificates:
- CE FCC
- Keywords:
- power inversor, inverter, power supplier